Logic

The Arcadia Logic module facilitates external control and conditional configuration.

GPI: Hardware on Arcadia, V-Series keypanel GPI 1 (in parallel with PTT on X7 variants), and virtual via I.V. Direct can be configured to control up to 10 audio crosspoints / call signals.

These can be used for:

  • Footswitches controlling audio

  • Automating Program Audio routing

  • Call signaling

  • 2-Way Radio Input Routing

GPO: Hardware on Arcadia, V-Series keypanel GPO 1 Panel Aux Relay), and virtual via I.V. Direct can be configured to activated from up to 10 audio crosspoints/call signals.

These can be used for:

  • Call signaling

  • On-Air or warning signals

  • 2-Way Radio Transmit Trigger

The Control Logic section facilitates conditional (if->then) logic using audio crosspoints, call signals and GPIO.

Hardware GPIO, V-Series keypanel GPIO 1, and I.V. Direct virtual GPIO are configured in the Configuration > Logic page of the Core Configuration Manager (CCM) and can be viewed and tested on the Status > Logic page.

Logic Page